Tests order as folllow: (the same order with EFBE):
out of phase the dynamic compression test (Phase 1) Compression resistance:+270N/-270N;
out of phase the dynamic compression test (Phase 1) Compression resistance: +350N/-350N;
in phase Handlebar Dynamic Compression Test Report (Phase 1) Compression resistance: +450N/-450N;
in phase Handlebar Dynamic Compression Test Report (Phase 1) Compression resistance: +600N/-600N;
out of phase the dynamic compression test (Phase 2) Compression resistance: +400N/-250N
out of phase Handlebar Dynamic Compression Test Report (Phase 2) Compression resistance:+300N/-550N;
in phase the dynamic compression test (Phase2) Compression resistance: +600N/-250N;
in phase Handlebar Dynamic Compression Test Report (Phase 2) Compression resistance:+1000N/-450N;
Over load test: (both sides)
(Phase 1) Compressive value: 1000N;
(Phase 2) Compressive value: 2500N;
MAX compressive value: 1878N broken.